Test of IBC containers

Drop Test

Fill the container with 98% testing liquid, reduce the temperature to -18, and drop from a height of 0.8-1.5 m.

Requirement: no crack, no leakage.

 

Leakage Test

Charge the container with air at 20Kpa, and maintain for 10 minutes at room temperature.

Requirement: no leakage.

 

Hydraulic Test

Fill the container with water at 100Kpa, and maintain for 10 minutes at room temperature.

Requirement: no crack, no leakage.

 

Stack Test

Fill the container with water at a nominal capacity of 98%; the loading value on the container top shall be 1.8 times the maximum allowable gross weight; and maintain for 24 hours at room temperature.

Requirement: no fall, no deformation, and no leakage.

 

Bottom Lift

Fill the container with water at a nominal capacity of 98%; the loading value on the container top shell be 1.25 times the maximum allowable gross weight; the fork of a forklift enters into 75% depth of the pallet; and lifts the container up and down twice from each side.

Requirement: no crack, no leakage.